Product Description

                                           

Electrical computer shielded control cable 

This product is suitable for a rated voltage of 300/500. V and electronic computers with higher requirements for anti-interference performance, Testing instruments, Instrument connection. Flame-retardant electronic computer shielding control cable 
Cable, fire-resistant computer shielded control cable, low-halogen low-smoke or halogen-free low-smoke flame-retardant cable Shielded cable for microcomputer control, also suitable for applications requiring flame retardancy, fire resistance, and low-smoke, non-toxic characteristics. 
A place of seeking. 

This product is authorized. The applicable standard is the enterprise standard. Q/HL127。


Product Usage Characteristics 

Rated voltage U/U For 300/500 V 。

Long-term permissible operating temperature of cable conductors: 70°C for polyethylene‑insulated and PVC‑insulated cables, and 90°C for cross‑linked polyethylene‑insulated cables. 

The cable laying temperature shall not be lower than 0°C. 

Fire-resistant control cables can pass GB/T19216 The specified test. 

Permissible bending radius of cables: For cables with an armor layer or copper‑tape shielding, the radius shall be no less than 12 times the cable’s outer diameter; for all other cables, the radius shall be no less than 6 times the cable’s outer diameter. 


Main Technical Specifications 

The DC resistance of conductors and the insulation resistance of cables at 20°C comply with the enterprise standard. Q/HL127。

The cable can withstand 2000. V/5min. Alternating voltage test. 

The operating capacitance of a cable pair at a frequency of IkHz Time ≤ 115 × 10 nF/km。

Flame-retardant shielded control cable for electronic computers can pass GB/T18380 specified A Class, B Class, C Classified combustion test. 

The fire-resistant computer shielded control cable can pass. GB/T19216 specified A Class, B Classified combustion test. 

Low-halogen, low-smoke, or halogen-free, low-smoke flame-retardant shielded cables for computer control can meet GB/T 18380 、 GB/T 17650 and GB/T 17651 Test requirements. 

Model, Name, Scope of Use 

Model number 

Name 

Use Environment 

Model, Name, Scope of Use 

Polyvinyl chloride‑insulated or cross‑linked polyethylene‑insulated twisted pair with aluminum‑plastic composite tape shielding, polyvinyl chloride… 
Shielded cable with ethylene jacket for computer control 

Installed in indoor environments, cable trenches, pipelines, and other fixed applications requiring shielding. 

Model number 

Name 

Use Environment 

DJYPIV 
DJVPIV 
DJYJPIV 

Polyvinyl chloride‑insulated or cross‑linked polyethylene‑insulated twisted pair with aluminum‑plastic composite tape shielding, polyvinyl chloride… 
Shielded cable with ethylene jacket for computer control 

Installed in indoor environments, cable trenches, pipelines, and other fixed applications requiring shielding. 

DJYPIV 22
DJVPIV22
DJYJP IV22

Copper‑core, polyethylene‑insulated, PVC‑insulated, or cross‑linked polyethylene‑insulated twisted pair with aluminum‑plastic composite. 
Shielded PVC‑jacketed steel‑tape armored shielded cable for computer control 

Laid indoors, in cable trenches, conduits, or directly buried, it can withstand substantial external mechanical forces. 
Fixed scenarios requiring blocking 

DJYPIV23
DJVPIV23
DJYJP I V23

Copper‑core, polyethylene‑insulated, PVC‑insulated, or cross‑linked polyethylene‑insulated twisted pair with aluminum‑plastic composite. 
Shielded polyethylene‑sheathed steel‑tape armored shielded cable for computer control 

Laid indoors, in cable trenches, conduits, or directly buried, it can withstand substantial external mechanical forces. 
Fixed scenarios requiring blocking 

DJYPIV32
DJVPIV32
DJYJP IV32

Copper‑core, polyethylene‑insulated, PVC‑insulated, or cross‑linked polyethylene‑insulated twisted pair with aluminum‑plastic composite. 
Shielded PVC‑jacketed, fine steel‑wire armored shielded cable for computer control 

It can withstand significant mechanical stress when installed indoors, in cable trenches, conduits, directly buried, or in shafts. 
Fixed applications requiring shielding against mechanical tension, etc. 

DJYPIV33
DJVPIV33
DJYJP IV33

Copper‑core, polyethylene‑insulated, PVC‑insulated, or cross‑linked polyethylene‑insulated twisted pair with aluminum‑plastic composite. 
Shielded polyethylene‑sheathed, fine steel‑wire‑armored shielded cable for computer control 

It can withstand significant mechanical stress when installed indoors, in cable trenches, conduits, directly buried, or in shafts. 
Fixed applications requiring shielding against mechanical tension, etc. 

DJYPIVP 1
DJVPIVPI 
DJYJPIVP1

Core‑in‑core, with ethylene insulation, PVC insulation, or cross‑linked ethylene insulation, twisted aluminum‑plastic composite tape. 
Shielded, aluminum-plastic composite tape overall shield, PVC jacket, shielded cable for computer control 

Installed in indoor environments, cable trenches, pipelines, and other fixed applications requiring shielding. 

DJY P2V
DJVP 2V
DJYJP2 V 

Copper‑core, polyethylene‑insulated, PVC‑insulated, or cross‑linked polyethylene‑insulated twisted pair with steel‑tape shielding. 
Shielded PVC‑jacketed shielded cable for computer control 

Installed in indoor environments, cable trenches, pipelines, and other fixed applications requiring shielding. 

DJYP 2V22
DJVP2V22
DJYJPZ V22

Copper‑core, polyethylene‑insulated, PVC‑insulated, or cross‑linked polyethylene‑insulated twisted pair with copper‑tape shielding. 
Shielded cable with PVC jacket and steel tape armor, for computer control applications 

Laid indoors, in cable trenches, conduits, or directly buried, it can withstand substantial external mechanical forces. 
Fixed scenarios requiring blocking 

DJYP 2V23
DJVP2V23
DJYJP 2V23

Copper‑core, polyethylene‑insulated, PVC‑insulated, or cross‑linked polyethylene‑insulated twisted pair with copper‑tape shielding. 
Shielded cable with polyethylene sheath and steel tape armor, for computer control applications. 

Laid indoors, in cable trenches, conduits, or directly buried, it can withstand substantial external mechanical forces. 
Fixed scenarios requiring blocking 

DJY P 2V32
DJVP2V32
DJYJP2V32

Copper‑core, polyethylene‑insulated, PVC‑insulated, or cross‑linked polyethylene‑insulated twisted pair with steel‑tape shielding. 
Shielded PVC‑jacketed, fine steel‑wire‑armored shielded cable for computer control 

It can withstand significant mechanical stress when installed indoors, in cable trenches, conduits, directly buried, or in shafts. 
Fixed applications requiring shielding against mechanical tension, etc. 

DJYP 2V33
DJVP 2V33
DJYJP2V33

Copper‑core, polyethylene‑insulated, PVC‑insulated, or cross‑linked polyethylene‑insulated twisted pair with copper‑tape shielding. 
Shielded polyethylene‑sheathed fine steel‑wire armored shielded cable for computer control 

It can withstand significant mechanical stress when installed indoors, in cable trenches, conduits, directly buried, or in shafts. 
Fixed applications requiring shielding against mechanical tension, etc. 

DJYP 2VP2
DJVP 2VP2
DJYJP2VP2

Steel‑core polyethylene‑insulated, PVC‑insulated, or cross‑linked polyethylene‑insulated twisted pair with steel‑tape shielding. 
Shielded, copper‑tape overall shield with a PVC jacket, shielded cable for computer control 

Installed in indoor environments, cable trenches, pipelines, and other fixed applications requiring shielding. 

D JY Photovoltaic 
DJVPV 
DJYJ Photovoltaic 

Copper‑core, polyethylene‑insulated, PVC‑insulated, or cross‑linked polyethylene‑insulated twisted pair with copper wire braiding. 
Shielded PVC‑jacketed shielded cable for computer control 

Installed in indoor environments, cable trenches, pipelines, and other fixed applications requiring shielding. 

DJYP Vice President 
DJVP Vice President 
DJYJ Vice President 

Copper‑core cable with ethylene insulation, PVC insulation, or cross‑linked polyethylene insulation, twisted copper wire braid shield. 
Shielded, copper‑wire‑braided overall shield with a PVC jacket, shielded cable for computer control 

Installed in indoor environments, cable trenches, pipelines, and other fixed applications requiring shielding. 

Model number 

Name 

Operating environment 

DJYPVR 
DJVPVR 
DJYJP VR 

Copper‑core, polyethylene‑insulated, PVC‑insulated, or cross‑linked polyethylene‑insulated twisted pair with copper wire braid shielding and a PVC jacket. 
Shielded flexible cable for electronic computer control 

For installation indoors where flexibility and shielding are required. 

DJYPVPR 
DJVPVPR 
DJYJP VPR 

Copper‑core, polyethylene‑insulated, PVC‑insulated, or cross‑linked polyethylene‑insulated twisted pair with steel‑wire braid shielding, overall copper‑wire braid. 
Shielded flexible cable with PVC jacket for computer control applications 

Laid indoors where flexibility and shielding are required. 
occasion 

DJYVP 
  DjVP 
DJYJVP 

Copper-core, polyethylene-insulated, PVC-insulated, or cross-linked polyethylene-insulated twisted pair with overall copper wire braid shielding, PVC jacket. 
Shielded cable for electronic computer control with sheath 

Installation in indoor spaces, cable trenches, pipelines, and other specified requirements 
Fixed scenarios for blocking 

DJYVP 
DJVVP
DJjYJV

Copper‑core, polyethylene‑insulated, PVC‑insulated, or cross‑linked polyethylene‑insulated twisted pair with overall shielding by an aluminum‑plastic composite tape. 
Shielded cable for electronic computer control with an ethylene jacket 

Laid indoors, in cable trenches, conduits, and other locations as required by the screen. 
Fixed occasions of concealment 

DJYVPR 
DJVVPR 
DJY JVPR 

Copper-core, polyethylene-insulated, PVC-insulated, or cross-linked polyethylene-insulated twisted pair with overall copper wire braid shielding, PVC jacket. 
Shielded flexible cable for electronic computer control 

For installation indoors where flexibility and shielding are required. 


In addition to manufacturing the aforementioned standard shielded heating elements for electronic computer control, our factory also produces flame-retardant shielded cables for electronic computer control and fire-resistant electronic computer control cables. 
Use shielded cables, low-halogen, low-smoke, or halogen-free, low-smoke flame-retardant shielded cables for computer control applications, among others. Their model designation methods are as follows: 
Flame-retardant shielded cables for electronic computer control shall be designated by adding a prefix to the standard cable model. ZA 、 ZB 、 ZC; 
Shielded cables for fire-resistant computer control shall be designated by adding a prefix to the standard cable designation. N; 
Low-halogen, low-smoke, and halogen-free, low-smoke flame-retardant power cables for computer control shall be prefixed with DDZA 、 DDZB 、 D DZC 、 WDZA 、 WDZB 、WDZC.

 

 

Product Inquiry